咨询热线

18948178581

当前位置:首页  >  产品展示  >    >    >  srs CIS Series-Closed ion source analyzers

srs CIS Series-Closed ion source analyzers

简要描述:srs CIS Series-Closed ion source analyzers

  • 产品型号:CIS
  • 厂商性质:经销商
  • 更新时间:2023-03-07
  • 访  问  量:579

详细介绍

  •  

srs CIS Series-Closed ion source analyzers

 

主要指标与说明With better than 1 ppm detection limit, direct sampling at mTorr pressure, and a user-friendly Windows software package, the CIS systems will satisfy your most demanding applications. On-line process monitoring and control, verification of process gas purity at the point of use, high-vacuum residual gas analysis, and process equipment leak checking are some of the areas where these systems will prove indispensable.

 

CIS Series Gas Analyzers100, 200, and 300 amu systems1 ppm detection10 mTorr max. operating pressure1 x 10-12 Torr detection limitReal-time RGA Windows softwareMulti-head operationRGA and CIS modeCIS Closed Ion Source Gas AnalyzersWith better than 1 ppm detection limit, direct sampling at mTorr pressure, and a user-friendly Windows software package, the CIS systems will satisfy your most demanding applications. On-line process monitoring and control, verification of process gas purity at the point of use, high-vacuum residual gas analysis, and process equipment leak checking are some of the areas where these systems will prove indispensable.Compact DesignThe probe consists of a quadrupole mass spectrometer with a CIS ionizer mounted inside a 2.75" Conflat? Tee. The control unit mounts directly on the probe’s feedthrough flange and contains all the necessary electronics for operating the instrument. The side port of the CIS nipple provides a connection for the differential pumping system that keeps the quadrupole, filament and detectorElectron Multiplierat high vacuum. The system can be connected directly to a process chamber through its standard CIS mounting flange (2.75" CF). The unit is self-aligning, with a simple, robust design. You can clean and reassemble the probe, and replace the filament and electron multiplier in the field, without ever calling the factory.Gold Plated IonizerThe entire ionizer is made of gold-plated stainless steel. This reduces outgassing and background signals in the ionization region, improves the long-term stability and permits operation while exposed to reactive and corrosiveGold Plated Ionizergases. A Tungsten filament is used, which resists corrosive and reactive gases like WF6 and silane, and leads to extended lifetime. The closed (gas tight) design of the ionizer prevents commonly interfering species from backstreaming into the ionization volume. This produces peaks free of spectral overlap.A Choice of DetectorsThe CIS series analyzers come standard with both a Faraday cup detector (10 ppm detection) and a continuous dynode electron multiplier (1 ppm detection). The software allows you to easily switch between detectors.

 

VersatilityThe CIS systems can also be used in a so-called "RGA mode". In this mode, the unit has a lower minimum detectable partial pressure, but a lower maximum operating pressure as well. The RGA mode is used, for example, in the first stage of a sputtering process when the chamber is evacuated to a low pressure, and the quality of the vacuum is checked for leaks and harmful contaminants. The unit can then be switched to a CIS mode for sampling directly at higher pressure.Complete ProgrammabilityA standard RS-232 interface is provided along with a complete programming reference. All probe parameters can be controlled and monitored, and data can be acquired for use in custom applications.Windows SoftwareAnalog ModePressure vs. TimeLibrary ModeThe CIS systems are supported with a real-time Windows software package that runs on PCs. The intuitive graphical user interface allows measurements to be made quickly and easily. The program is fully interactive, giving the user complete control of the graphical display. Screens can be split for dual-mode operation, scales can be set to linear or log format, and data can be scaled manually or automatically. Data is captured and displayed in real-time or scheduled for acquisition at a given interval for long-term data logging. Features include user-selectable units (ppm, Torr, mbar, Pa and A), programmable audio and visual alarms, and comprehensive, on-line help. The software allows complete CIS head control with easy mass scale tuning, sensitivity calibration, ionizer setup, and electron multiplier gain adjustment. For further analysis, data files can be saved in ASCII format for easy transfer into spreadsheets. Graphic images can be saved as META files or copied to the clipboard for importing into other Windows programs. The software also provides password protection for locking out head parameters so that casual users can’t alter important settings.An optional stand-alone monitor (PPM100) can be used to control the RGA without a host computer.Multi-Head OperationThe software supports multiple head operation when more than one CIS is needed. Up to eight ECUs can be monitored from the software.Pumping RequirementsThe CIS instruments require connection to a pumping system with an effective pumping speed of at least 40 L/s and a base pressure of less than 10-9 Torr. The connection port is a 2.75" Conflat? flange. Option O100TDP provides a turbo pump which mounts directly to the CIS head along with a diaphragm roughing pump. When this option is ordered the entire analyzer is assembled, tested, and calibrated at the factory. Users can provide their own pumping station; however, it is the user’s responsibility to ensure that the pumping system does not damage or limit the performance of the instrument.Affordable PerformanceThe SRS CIS systems offer state-of-the-art performance for a fraction of the cost of competing models. Standard systems include faraday cup detector, electron multiplier detector and Windows software. Options include built-in power module for AC line operation, and a pumping package that includes a turbomolecular pump and diaphragm pump.

 

CIS Dimensional DrawingCIS Parameter Range CIS mode RGA modeElectron emission current (mA) 0 to 1 0.05 0.5Electron energy (eV) 25 to 105 70 or 35 70Ion energy (eV) 4 or 8 4 or 8 4 or 8Extraction voltage (V) 0 to -150 -50 (typ.) -50 (typ.)Sensitivity (A/Torr)(for N2 @ 28 amu) 10-6 10-5Linear range upper limit (Torr) 2 × 10-3 10-4MDPP (Torr) 10-8 10-9Notes1. The CIS tests were performed with a 70 L/s hybrid turbomolecular pump, backed by a diaphragm pump, attached to the side port of the CIS Cover Tee.2. The RGA mode sensitivities reported were calculated for N2 at less than 10-5 Torr.3. The CIS mode sensitivities were calculated for N2 at 1 to 5 × 10-4 Torr.4. MDPP (minimum detectable partial pressure) is determined by measuring baseline levels for Faraday cup detection in the presence of 28N2 at 10-5 (RGA mode) and 10-3 Torr (CIS mode). Up to 3 orders of magnitude improvement in detectability is possible when the electron multiplier is turned on.CIS Closed Ion Source Gas AnalyzersOperationalMass Range CIS100 1 to 100 amu CIS200 1 to 200 amu CIS300 1 to 300 amuMass filter type QuadrupoleDetector type Faraday cup and electron multiplierResolution (per AVS std. 2.3) Better than 0.5 amu @ 10 % peak height. Adjustable to constant peak width throughout mass range.Max. operating temp. 70 °CBakeout temperature 300 °C (without ECU)IonizerDesign Closed ion source, cylindrical symmetry, electron impact ionizationMaterial Gold plated SS304Filament Tungsten or ThO2/Ir with firmware protection (field replaceable)Electron energy 25 to 105 eV, programmableIon energy 4 or 8 eV, programmableFocus voltage 0 to 150 V, programmableElectron emission current 0 to 1 mA, programmableGeneralProbe mounting flange 2.75" CFECU dimensions 4.1" × 3.1" × 9.1" (WHL). Easily separated from the probe for bakeout.LED indicators Power ON/OFF, filament ON/OFF, electron multiplier ON/OFF, RS-232 Busy, Error, Overpressure, Burnt FilamentWarm-up time Peak height ±2 % after 3 minutes. Mass stability ±0.1 amu after 30 minutes.Computer interface RS-232C, 28,800 baud with high-level command setSoftware Windows based applicationPower requirement 24 VDC @ 2.5 amps. Male DB9 connector, optional built-in power module for AC line operationWeight 6 lbs.Warranty One year parts and labor on defects in materials and workmanship

 

Agilent 83497A 光电时钟恢复模块

 

Agilent 8157A 光衰减仪

 

Agilent 81637B 快速功率计

 

Agilent 34570A 数字万用表

 

Agilent 44476A 微波复用器模块

 

Agilent 70004A 光谱分析仪

 

Agilent 81000FI 光纤连接器

 

Agilent 81002FF 积分球

 

Agilent 81521B 光功率计探头

 

Agilent 81524A 光功率探头

 

Agilent 81525A 大功率光学探头

 

Agilent 81533A 接口模块

 

Agilent 81533B 接口模块

 

Agilent 81536A 光功率计传感插件

 

Agilent 81560A 可变光衰减器

 

Agilent 81567A 可变光衰减器模块

 

Agilent 8156A 光衰减器

 

Agilent 81578A可变光衰减器模块

 

Agilent 81610A回损测试模块

 

Agilent 81619A 光功率模块

 

Agilent 81624A 光学探头

 

Agilent 81625A 光功率探头

 

Agilent 81633A 分布式反馈(DFB)激光器

 

Agilent 81635A 双光功率传感器

 

Agilent 8163A光功率计主机

 

Agilent 8163B 光功率计

 

Agilent 8164A 光波测量系统主机

 

Agile

产品咨询

留言框

  • 产品:

  • 您的单位:

  • 您的姓名:

  • 联系电话:

  • 常用邮箱:

  • 省份:

  • 详细地址:

  • 补充说明:

  • 验证码:

    请输入计算结果(填写阿拉伯数字),如:三加四=7