咨询热线

18948178581

当前位置:首页  >  产品展示  >    >    >  srs SR715-100 kHz LCR meters

srs SR715-100 kHz LCR meters

简要描述:srs SR715-100 kHz LCR meters

  • 产品型号:SR715
  • 厂商性质:经销商
  • 更新时间:2023-03-07
  • 访  问  量:632

详细介绍

  •  

srs SR715-100 kHz LCR meters

 

主要指标与说明The SR715 LCR and SR720 LCR Meters measure passive components with as little as 0.05 % error. These easy-to-use instruments are quick to setup, adjust and calibrate. The SR715 and SR720 are ideal for applications such as incoming inspection, quality control, automated test, and general benchtop use.

 

SR715 and SR720 LCR Meters0.05 % basic accuracy (SR720),0.2 % basic accuracy (SR715)5-digit display of L, C, R & Q or DTest frequencies to 100 kHzUp to 20 measurements per secondBinning and limitsExt. capacitor bias up to 40 VRS-232, GPIB & handler interfacesSR715 and SR720 LCR MetersThe SR715 LCR and SR720 LCR Meters measure passive components with as little as 0.05 % error. These easy-to-use instruments are quick to setup, adjust and calibrate. The SR715 and SR720 are ideal for applications such as incoming inspection, quality control, automated test, and general benchtop use.Front-Panel DisplayA 5-digit LED display shows measured values, entered parameters, instrument status, and user messages. When making measurements, the major parameter (L, C or R) is shown on the left display and the appropriate minor parameter (Q, D or R) is shown on the right display.Making MeasurementsMeasurements can be performed at test frequencies of 100 Hz, 120 Hz, 1 kHz, 10 kHz and 100 kHz (SR720 only). A built-in drive voltage can be set to preset values (0.1, 0.25 and 1.0 V) or adjusted from 0.1 to 1.0 V in 50 mV increments.Measurements are taken at rates of 2, 10 or 20 samples per second. Consecutive readings can be averaged between 2 and 10 times for increased accuracy. Both series or parallel equivalent circuit models of a component are supported. Capacitor measurements use either the internal 2.0 VDC bias or an external DC source of up to 40 volts.Simple to OperateThe power and flexibility of the SR715/720 does not come at the expense of ease-of-use. A convenient AUTO measurement mode automates the selection of setup parameters and quickly determines the appropriate device model for whatever component is being measured. Up to nine instrument setups can be stored in non-volatile memory for quick recall at a later time.Convenient CalibrationThe SR715 and SR720 make it simple to compensate for lead impedance and stray fixture and cable capacitance. The null calibration procedure automatically corrects both open and short circuit parameters at all frequencies and all ranges. BinningThe SR715 and SR720 have built-in features to aid in component sorting. this especially useful for production testing, incoming inspection, device matching, or when you need to test multiple devices of similar value. The meters allow you to sort components into as many as ten different bins.The SR715 and SR720 support three types of binning schemes: pass/fail, overlapping and sequential. Pass/Fail has only two bins; good parts and everything else. Overlapping (or nested) bins have one nominal value and are sorted into progressively larger bins (e.g., ±1 %, ±2 %, ±3 %). Sequential bins can have different nominal values, each separated by a percentage or a nominal value and asymmetrical limits. Binning parameters are also easily stored in non-volatile RAM for quick setup in production environments.

 

Test FixturesThe SR715 and SR720 have a kelvin fixture which uses two wires to carry the test current and two independent wires to sense the voltage across the device under test. This prevents the voltage drop in the current carrying wires from affecting the voltage measurement. Radial components are simply inserted into the test fixture, one lead in each side. Axial devices require the use of the axial fixture adapters (provided). Surface-mount devices, or components with large or unusually shaped leads, can be measured with optional SMD Tweezers (SR727) or Kelvin Clips (SR726). The tweezers and clips attach directly to the LCR meter’s front-panel test fixture. An optional BNC Fixture Adapter (SR728) allows you to connect a remote fixture or other equipment through one meter of coaxial cable.Rear PanelTwo rear-panel input connections are provided for an external bias voltage. Voltages as high as 40 VDC can be used. An optional handler interface provides control lines to a component handler for sorting. A standard RS-232 interface allows complete control of all instrument functions by a remote computer. A GPIB interface is included with the handler option.SR715 and SR720 LCR MetersSpecifications Measurement modes Auto, R+Q, L+Q, C+D, C+REquivalent circuit Series or parallelParameters displayed Value, Deviation, % Deviation or Bin Number (Deviation and % Deviation are calculated relative to a stored value.)Basic accuracy SR715: 0.2 %, SR720: 0.05 %Measurement Range(R+Q mode) R 0.0001 Ω to 2000 MΩ Q 0.00001 to 50(L+Q mode) L 0.0001 μH to 99999 H Q 0.00001 to 50(C+D mode) C 0.0001 pF to 99999 μF D 0.00001 to 10(C+R mode) C 0.0001 pF to 99999 μF R 0.00001 Ω to 99999 kΩElectricalTest frequency Fixed frequencies at 100 Hz, 120 Hz,1 kHz, 10 kHz (SR715 and SR720), 100 kHz (SR720 only)Frequency accuracy ±100 ppmDrive voltage Preset levels: 0.10, 0.25, 1.0 VrmsVernier: 0.1 to 1.0 Vrms with 50 mV resolutionDrive level accuracy ±2 %Bias voltage Internal: 2.0 VDC ± 2 %External: 0 to +40 VDC, fused @ 250 mAFeaturesAveraging 2 to 10 measurementsMeasurement rate Slow, Medium, Fast: 2, 10 or 20 measurements per second at test frequencies of 1 kHz and above and about 0.6, 2, 4 or 6 measurements per second at 100 Hz and 120 Hz.Ranging Auto or ManualTriggering Continuous, manual or remote over RS-232, GPIB or Handler interfaceBinning Up to 8 pass bins, QDR and general fail bins, defined from the front panel or over the computer interfaces. Binning setup may be stored in non-volatile memory.

 

FixtureFixture 4-wire kelvin fixture for radial leaded parts with adapters for axial leaded parts.Fixture protection Protected up to 1 Joule of stored energy and 200 VDC (for charged capacitors). Fused at 0.25 A output current for biased measurement.CalibrationZeroing Open and short circuit compensationCompensation limits Short: R <20 Ω, Z <50 Ω, Open: Z >10 kΩGeneralStore and recall Store/recall up to nine complete instrument setups.RS-232 Standard interface. All instrument functions can be controlled or read over the interface.GPIB and Handler (SR720) IEEE-488.2 and Handler interface. Handler interface uses a DB25 connector, positive logic for binning and control.Operating temperature 0 °C to 35 °CRelative humidity <85 %Power 20 W, 100/120/220/240 VAC, 50 or 60 HzDimensions 13.5" × 4" × 14" (WHL)Weight 10 lbs.Warranty One year parts and labor on defects in materials and workmanship

 

Agilent 83497A 光电时钟恢复模块

 

Agilent 8157A 光衰减仪

 

Agilent 81637B 快速功率计

 

Agilent 34570A 数字万用表

 

Agilent 44476A 微波复用器模块

 

Agilent 70004A 光谱分析仪

 

Agilent 81000FI 光纤连接器

 

Agilent 81002FF 积分球

 

Agilent 81521B 光功率计探头

 

Agilent 81524A 光功率探头

 

Agilent 81525A 大功率光学探头

 

Agilent 81533A 接口模块

 

Agilent 81533B 接口模块

 

Agilent 81536A 光功率计传感插件

 

Agilent 81560A 可变光衰减器

 

Agilent 81567A 可变光衰减器模块

 

Agilent 8156A 光衰减器

 

Agilent 81578A可变光衰减器模块

 

Agilent 81610A回损测试模块

 

Agilent 81619A 光功率模块

 

Agilent 81624A 光学探头

 

Agilent 81625A 光功率探头

 

Agilent 81633A 分布式反馈(DFB)激光器

 

Agilent 81635A 双光功率传感器

 

Agilent 8163A光功率计主机

 

Agilent 8163B 光功率计

 

Agilent 8164A 光波测量系统主机

 

Agilent 81650A 单法布里-珀罗激光源

 

Agilent 81651A 光源模块

 

Agilent 81654A 法布里-珀罗激光源

 

Agilent 81662A 分布式反馈(DFB)激光器

 

Agilent 8168E 可调谐激光源

 

Agilent 83440D光波转换器

 

Agilent 83480A 数字通信分析仪

 

Agilent 83483A 双通道电模块

 

Agilent 83486A 光电模块

 

Agilent 83487A 光电模块

 

Agilent 83492A 多模时钟模块

 

Agilent 83493A 单模时钟恢复模块

 

Agilent 83494A 单模时钟恢复模块

 

Agilent 83495A 时钟恢复模块

 

Agilent 83496A 光电时钟恢复模块

 

Agilent 86100A 光示波器

 

Agilent 86100C 宽带示波器主机

 

Agilent 86103A 光电模块

 

Agilent 86103B 光电模块

 

Agilent 86105A 光电模块

 

Agilent 86105B 光电模块

 

Agilent 86106B 光电模块

 

Agilent 86107A 精密时基参考模块

 

Agilent 86120B 多波长计

 

Agilent 86120C 多波长计

 

Agilent 86142B 高性能光谱分析仪

 

Agilent 86146b 光谱分析仪

 

Agilent N7740 多端口光功率计

 

Ando AQ2140光功率计

 

Ando AQ2730光功率计模块

 

Ando AQ2742 光功率传感器

 

Ando AQ2743 光功率传感器

 

Ando AQ4211LD组件

 

Ando AQ4215 光功率计

 

Andu AQ-4137 光源

 

Andu AQ-4142 光源

 

Anritsu 69347B 信号源

 

Anritsu MN9610B光衰减器

 

Anritsu ms9710c 光谱分析仪

 

Anritsu MS9740A 台式光谱分析仪

 

CVI Melles Griot 05-LHP-211-1 激光器

 

Ericsson FSU-975 光纤熔接机

 

Exfo IQS-3150 可变衰减器

 

EXFO WA-1650 光波长计

 

HP 8153A 光功率计

 

HP 8153B 光波万用表

 

HP 81551MM 点光源模块

 

HP 83540A 插件信号源

 

HP 8595E 频谱分析仪

 

IFR GPS-101定位系统模拟器

 

Jdsu HA9 光衰减器

 

JDSU OLP-55 光功率计

 

Keithley 7001半导体开关系统

 

Keithley 2001A 数字多用表

 

Keithley 2400 数字源表

 

Keithley 2400-C 数字源表

 

Keithley 2500 数字源表

 

Keithley 2502 数字源表

 

产品咨询

留言框

  • 产品:

  • 您的单位:

  • 您的姓名:

  • 联系电话:

  • 常用邮箱:

  • 省份:

  • 详细地址:

  • 补充说明:

  • 验证码:

    请输入计算结果(填写阿拉伯数字),如:三加四=7