srs SR400-Gated photon counter (2 ch.)

 

主要指标与说明The SR400 Dual-Channel Gated Photon Counter offers a convenient, integrated approach to photon counting that avoids the complexity and expense of older counting systems. No longer is it necessary to mix and match amplifiers, discriminators, gate generators and counters. The SR400 combines all these modules into a single, integrated, microprocessor controlled instrument.

 

SR400 Gated Photon CounterTwo independent channelsCount rates to 200 MHz5 ns pulse-pair resolutionGated and continuous modesGate scanningBuilt-in discriminatorsGate and discriminator outputsGPIB and RS-232 interfacesSR400 Gated Photon CounterThe SR400 Dual-Channel Gated Photon Counter offers a convenient, integrated approach to photon counting that avoids the complexity and expense of older counting systems. No longer is it necessary to mix and match amplifiers, discriminators, gate generators and counters. The SR400 combines all these modules into a single, integrated, microprocessor controlled instrument. Complex measurement tasks such as background subtraction, synchronous detection, source compensation and pile-up correction can all be performed easily with the SR400.CountersThe SR400 has two independent channels that can count at rates up to 200 MHz. Different counting modes allow you to count for a fixed amount of time, until a certain number of counts have been received, or for a fixed number of triggers. Each counting channel has its own gate generator providing counting gates as short as 5 ns or as long as 1 s. The gates can be set in a fixed position relative to the trigger signal, or scanned to measure lifetimes or recover time-varying waveforms.The actual inputs to the counters can be viewed as NIM level pulses from the discriminator outputs on the front panel. The discriminated pulses are negative going from 0 to -0.7 V. The DISC outputs are very useful when adjusting discriminator thresholds or gate timing.Signal Inputs and DiscriminatorsBoth analog signal inputs (A and B) are internally terminated into 50 Ω. The inputs accept signals between ±300 mV and are protected to ±5 VDC. Each input is followed by a DC to 300 MHz amplifier, allowing detection of pulses as small as 10 mV. If additional sensitivity is required, a remote preamplifier (like the SR445A) can be used.Discriminators are provided for each channel with a selectable threshold from -300 mV to +300 mV in 0.2 mV steps. Pulse-pair resolution is 5 ns, and pulses of either polarity may be detected. Each threshold may be programmed to scan in either direction with selectable step size. This can provide a pulse height analysis (PHA) output and is useful for choosing photomultiplier tube bias or discriminator levels.Count PeriodsThe SR400 may be programmed to cycle from 1 to 2000 count periods in a single scan. At the end of the programmed scan, the counters may be stopped or the scan may be restarted. Consecutive count periods are separated by a "Dwell Time" which can be set from 2 ms to 60 s. During the Dwell Time, counting is disabled and data may be transferred or external parameters may be changed. The dwell output provides a TTL signal which is high during the dwell time. This can be convenient for interfacing other instruments used in the experiment.

 

OutputsThe front panel can display counts up to 109. Results from both counters can be displayed individually or combined as A-B or A+B. A front-panel D/A output provides an analog signal proportional to A, B, A-B, or A+B, depending on the counting mode. The scale may be logarithmic (1V/decade) or linear.Computer InterfacesBuilt-in RS-232 and GPIB interfaces provide a convenient means of controlling the instrument and retrieving data. While the SR400 is scanning, each of the count values for the A and B counters are stored in a 2000 point internal buffer. This buffer can be transferred on a point-by-point basis, or dumped all at once through either interface.SR400 Gated Photon CounterSignal Inputs Bandwidth DC to 300 MHzInput impedance 50 ΩLinear range ±300 mV (at input)Input protection ±5 VDC, 50 V for 1 μsOverload recovery 5 ns DiscriminatorsCounters A, B, and T have independent discriminators when counting the signal inputs. All discriminator levels may be set to a fixed level or scanned. Discriminator range -300 mV to +300 mVDiscriminator slope Rising or fallingResolution 0.2 mVInput offset voltage <1 mVMinimum pulse input 10 mVPulse-pair resolution 5 nsDISC outputs NIM levels into 50 ΩInhibit input TTL high stops countTrigger Input Impedance 10 kΩThreshold ±2.000 VDC in 1 mV stepsSlope Rising or fallingProtection 15 VDC, 100 V for 1 μsGate GeneratorsBoth the A and B gates may be fixed in time or scanned. The gate outputs show the positions of the gates with respect to the discriminator outputs. Insertion delay 25 nsMaximum delay 999.2 msMinimum gate width 5 nsMaximum gate width 999 ms or CWResolution 0.1 %, 1 ns minimumAccuracy 2 ns + 1 %Jitter 200 ps rms +100 ppmMaximum trigger rate 1 MHzGATE view output NIM levels into 50 ΩGATE view error <2 ns

 

Scan and DwellThe number of count periods or data points in a scan may be set from 1 to 2000. The duration of one count period is determined by the preset condition.The time between consecutive count periods is the dwell time and can be set from 2 ms to 60 s. The dwell output will be TTL high during the dwell time. This output can be used to trigger external devices. At the end of a scan (of 1 to 2000 count periods), counting may be programmed to stop or start the scan over again. The start key begins the first count period of the programmed scan.The stop key terminates the current count period and pauses the scan. If scanning, gates and disc levels are held at their current values. Pressing the stop key while in a paused condition will reset the scan, and all scanned parameters will return to their start values. Pressing the start key while paused resumes the scan by starting the next count period.The dwell time may also be set to external. In this mode, count periods begin with the start key or external start input (TTL rising edge). Count periods terminate with the preset condition, the stop key, or the external stop input (TTL rising edge). Pressing the stop key while not counting resets the scan.All count data is internally buffered for one scan. Data may be read over the computer interfaces during or after a scan.Display ModeContinuous Displays current counter valueHold Displays final count valueD/A OutputThe front-panel D/A output is proportional (linear or log) to A, B, A-B or A+B, and is updated at the end of each count period. There are two rear-panel D/A outputs: port 1 and port 2. These outputs may be set or scanned from the front panel or via the computer interface. Full scale ±10 VDCResolution 12 bits (5 mV)Current rating 10 mAOutput impedance <1 ΩAccuracy 0.1 % + 5 mVGeneralInterfaces GPIB and RS-232Dimensions 16" × 3.5" ×13" (WHL)Weight 10 lbs.Power 35 W, 100/120/220/240 VAC, 50/60 HzWarranty One year parts and labor on defects in materials and workmanship

 

Agilent 83497A 光电时钟恢复模块

 

Agilent 8157A 光衰减仪

 

Agilent 81637B 快速功率计

 

Agilent 34570A 数字万用表

 

Agilent 44476A 微波复用器模块

 

Agilent 70004A 光谱分析仪

 

Agilent 81000FI 光纤连接器

 

Agilent 81002FF 积分球

 

Agilent 81521B 光功率计探头

 

Agilent 81524A 光功率探头

 

Agilent 81525A 大功率光学探头

 

Agilent 81533A 接口模块

 

Agilent 81533B 接口模块

 

Agilent 81536A 光功率计传感插件

 

Agilent 81560A 可变光衰减器

 

Agilent 81567A 可变光衰减器模块

 

Agilent 8156A 光衰减器

 

Agilent 81578A可变光衰减器模块

 

Agilent 81610A回损测试模块

 

Agilent 81619A 光功率模块

 

Agilent 81624A 光学探头

 

Agilent 81625A 光功率探头

 

Agilent 81633A 分布式反馈(DFB)激光器

 

Agilent 81635A 双光功率传感器

 

Agilent 8163A光功率计主机

 

Agilent 8163B 光功率计

 

Agilent 8164A 光波测量系统主机

 

Agilent 81650A 单法布里-珀罗激光源

 

Agilent 81651A 光源模块

 

Agilent 81654A 法布里-珀罗激光源

 

Agilent 81662A 分布式反馈(DFB)激光器

 

Agilent 8168E 可调谐激光源

 

Agilent 83440D光波转换器

 

Agilent 83480A 数字通信分析仪

 

Agilent 83483A 双通道电模块

 

Agilent 83486A 光电模块

 

Agilent 83487A 光电模块

 

Agilent 83492A 多模时钟模块

 

Agilent 83493A 单模时钟恢复模块

 

Agilent 83494A 单模时钟恢复模块

 

Agilent 83495A 时钟恢复模块

 

Agilent 83496A 光电时钟恢复模块

 

Agilent 86100A 光示波器

 

Agilent 86100C 宽带示波器主机

 

Agilent 86103A 光电模块

 

Agilent 86103B 光电模块

 

Agilent 86105A 光电模块

 

Agilent 86105B 光电模块

 

Agilent 86106B 光电模块

 

Agilent 86107A 精密时基参考模块

 

Agilent 86120B 多波长计

 

Agilent 86120C 多波长计

 

Agilent 86142B 高性能光谱分析仪

 

Agilent 86146b 光谱分析仪

 

Agilent N7740 多端口光功率计

 

Ando AQ2140光功率计

 

Ando AQ2730光功率计模块

 

Ando AQ2742 光功率传感器

 

Ando AQ2743 光功率传感器

 

Ando AQ4211LD组件

 

Ando AQ4215 光功率计

 

Andu AQ-4137 光源

 

Andu AQ-4142 光源

 

Anritsu 69347B 信号源

 

Anritsu MN9610B光衰减器

 

Anritsu ms9710c 光谱分析仪

 

Anritsu MS9740A 台式光谱分析仪

 

CVI Melles Griot 05-LHP-211-1 激光器

 

产品咨询

留言框

  • 产品:

  • 您的单位:

  • 您的姓名:

  • 联系电话:

  • 常用邮箱:

  • 省份:

  • 详细地址:

  • 补充说明:

  • 验证码:

    请输入计算结果(填写阿拉伯数字),如:三加四=7