咨询热线

18948178581

当前位置:首页  >  产品展示  >    >    >  srs SR430-Multi-channel scaler / averager

srs SR430-Multi-channel scaler / averager

简要描述:srs SR430-Multi-channel scaler / averager

  • 产品型号:SR430
  • 厂商性质:经销商
  • 更新时间:2023-03-07
  • 访  问  量:699

详细介绍

品牌Scale/仁沃
  •  

srs SR430-Multi-channel scaler / averager

 

主要指标与说明The SR430 is the first multichannel scaler which combines amplifiers, discriminators, bin clocks, and data analysis in a single, integrated instrument. With its many features and its easy-to-use menu driven interface, the SR430 simplifies time-resolved photon counting experiments.

 

SR430 Multi-Channel Scaler5 ns to 10 ms bin widthCount rates up to 100 MHz1k to 32k bins per recordBuilt-in discriminatorNo interchannel dead timeOn-screen data analysisGPIB and RS-232 interfacesSR430 Multi-Channel Scaler/AveragerThe SR430 is the first multichannel scaler which combines amplifiers, discriminators, bin clocks, and data analysis in a single, integrated instrument. With its many features and its easy-to-use menu driven interface, the SR430 simplifies time-resolved photon counting experiments.The SR430 Multichannel Scaler/Averager can be thought of as a photon counter that counts events as a function of time. A trigger starts the counter which segments photon count data into sequential time bins (up to 32k bins). The width of the bins can be set from 5 ns to 10 ms. The instrument records the number of photons that arrive in each bin.The SR430 is useful in a variety of applications where it is necessary to count events as a function of time: LIDAR, time of flight mass spectroscopy, and fluorescence decay measurements are just a few examples.Input and DiscriminatorThe SR430’s analog input has a 50 Ω input impedance and an input range of ±300 mV. The maximum input sensitivity is 10 mV, and if your input signal level is less than this a preamplifier (like the SR445) should be used. The input is followed by a discriminator with a selectable slope and a threshold adjustable between ±300 mV. A discriminator BNC output is provided at the front panel that generates a NIM level (0-.7 V, active low) signal corresponding to each count.SR430 Timing DiagramTrigger TimingA trigger pulse starts the data acquisition cycle. The SR430 offers a choice of bin widths ranging from 5 ns to 10.486 ms. Alternatively, an external bin clock can be provided to the SR430, allowing you to define your own bin size.The number of bins in each record is adjustable from 1k (1024) to 32k in 1k increments. Data acquisition in the SR430 is seamless-there is no dead time between bins. Once the selected number of bins has been recorded, the SR430 either adds or subtracts the result of the current record from the accumulated bin totals.

 

AccumulationThe SR430 can be programmed to accumulate between one and 64k records, or set to free run. Each record can be added or subtracted from the current accumulator totals. The instrument can be set to toggle between add and subtract every N records, or an external toggle input can select the polarity of the next record. A rear-panel inhibit input allows you to selectively prevent the accumulation of any given record. The screen display is updated continuously as records are accumulated, providing a live, real-time display of the data.Analysis MenuModes MenuLevels MenuData DisplayThe 7" CRT screen allows complete flexibility in displaying your results. Between 8 and 16k bins can be displayed on the screen at any time, and complete horizontal and vertical zooming and scrolling features are provided. An "Autoscale" key quickly optimizes the screen for the current data with a single keypress. A fast, responsive, on-screen cursor lets you read the maximum, minimum or mean data value from a selected range of the graph.Menus and SoftkeysThe SR430 is based on a simple, menu-based user interface. Each menu groups related instrument functions and defines softkeys to control those functions. The instrument settings are changed by pressing the softkeys or by turning the front-panel knob. Complete context sensitive help is provided for all menus and softkeys. The remote command list is also provided on a help screen as an aid in programming the SR430.Data AnalysisThe SR430's extensive capabilities don't stop with data acquisition. Savitsky-Golay smoothing can be applied to any portion of the data, with selectable smoothing intervals. Gaussians, exponentials or straight lines can be fit to arbitrary regions of the display, allowing you to quickly determine decay lifetimes. Basic statistical parameters can be calculated for data regions including total number of counts, mean number of counts, and variance. Basic arithmetic operations, including addition, subtraction, multiplication, division, logs and square roots, can be applied to the current data.Built-In Disk DriveThe SR430 has a built-in 3.5" DOS-compatible disk drive to simplify data transfer between the instrument and your computer. Both data files and settings files can be stored so you can save complete instrument setups for a variety of situations and recall them instantly.Hardcopy OutputHardcopy output is available from the SR430 in a variety of forms. A standard Centronics printer port lets you dump the screen to dot-matrix or LaserJet compatible printers at any time. Additionally, the SR430 can plot its display on any HP-GL compatible plotter via the RS-232 or GPIB interface.

 

Complete ProgrammabilityBoth RS-232 and GPIB interfaces are standard on the SR430 ensuring compatibility with the widest range of laboratory computers. All instrument settings and functions can be read and set via the interfaces. A complete list of all characters received and transmitted over the interfaces can be displayed on the CRT screen-an invaluable aid when debugging your programs. Numerous modes are available for downloading the count data to your computer including ASCII transfer, binary transfer, and a fast binary dump mode which transfers data continuously over the GPIB interface as it is being acquired by the instrument.SR430 Multi-Channel Scaler/AveragerSignal Input Bandwidth DC to 250 MHzInput impedance 50 ΩLinear range ±300 mV (at input)Input protection ±5 VDC, 50 V for 1 μsOverload recovery 5 ns for <10 μs duration overload DiscriminatorDiscriminator range -300 mV to +300 mVResolution 0.2 mVSlope Positive or negativeAccuracy 2 mV + 1 %Min. pulse amplitude 10 mVPulse pair resolution 10 ns (typ.)DISC view output NIM level into 50 Ω. (There is a 20 ns insertion delay from the signal input to the discriminator output.)Trigger InputImpedance 10 kΩThreshold -2.000 V to +2.000 V in 1 mV stepsSlope Rising or fallingProtection 15 VDC, 100 V for 1 μsInternal Time BinsBin width 5 ns, 40 ns, 80 ns, 160 ns, 320 ns, 640 ns, 1.28 μs, 2.56 μs,...10.486 ms. (10 ns and 20 ns are not available)Accuracy 1 ns + 20 ppm of bin widthJitter (RMS) 100 ps + 10 ppm of delay from SYNC/BUSY output (bins are synchronous with SYNC/BUSY output)Indeterminacy 2.5 ns with respect to trigger input Insertion delay 45 ns from trigger to first bin. Rising edge of SYNC/BUSY output occurs at beginning of first bin. Signal pulses arriving 25 ns after the trigger will be counted in the first bin.Externally Clocked Time BinsEXT BIN CLK input Rising edge triggers next time binMaximum frequency 4 MHz (250 ns minimum bin width)Minimum time high 100 nsMinimum time low 100 nsInsertion delay Rising edge of SYNC/BUSY output occurs at first rising edge of EXT BIN CLK after trigger. The beginning of the first bin occurs at the same time.Counters/AccumulationBins per record 1k to 16k in 1k increments (1024 to 32,704 including trigger offset)Max. count rate 100 MHzMax. count 32,767 per bin per triggerRecords/accumulation 1 to 64k (or free run)Max. accumulation 32,767 per bin in Add mode, ±16,383 per bin in Toggle or External modeAdd/subtract Records may be added or toggled (add/subtract on alternating triggers). External subtract input may also control the toggle.Trigger RateMinimum trigger time Tp = (# of bins × bin width) + (# of bins × 250 ns) + 150 μs SYNC/BUSY output is high for Tp after each trigger. When SYNC/BUSY returns low, the next record may be triggered. Triggers received while SYNC/BUSY is high are ignored.OutputsDISC NIM level into 50 Ω. Low whenever signal input exceeds discriminator level with the correct slope.SYNC/BUSY TTL level. Rising edge is synchronous with first time bin of each record. Remains high until re-armed for next trigger.BIN CLK OUTPUT NIM level into 50 Ω. Each transition is a bin boundary. Active only while a record is being acquired. Timing skew relative to DISC out is <2 ns.TOGGLE TTL level. Indicates whether the next record will be added to or subtracted from the accumulation. (Internal toggle mode)TEST 50 MHz NIM output into 50 ΩAUX1, AUX2 (General purpose analog outputs) Full scale ±10 V Resolution 5 mV Output current 10 mA Output impedance <1 Ω Accuracy 0.1 % + 10 mVInputsSIGNAL Analog 50 Ω inputTRIGGER 10 kΩ inputBIN CLK INPUT TTL input. Rising edge triggers next time bin.ACC. INHIBIT TTL input, sampled each trigger. If high, causes

产品咨询

留言框

  • 产品:

  • 您的单位:

  • 您的姓名:

  • 联系电话:

  • 常用邮箱:

  • 省份:

  • 详细地址:

  • 补充说明:

  • 验证码:

    请输入计算结果(填写阿拉伯数字),如:三加四=7